1, turbocharger does not change direction
Cause: Energy converter blocked;
Elimination method: cleaning or replacement.
2, turbocharger has a crash sound
Cause: Buffer damping is small;
Elimination method: Adjust the double one-way throttle valve to eliminate the crash sound.
3, high pressure water hair scattered
Cause: Damaged energy converter;
Elimination method: Replace the energy converter
4, no high pressure water comes out
Cause: The energy converter is blocked (at this time the hydraulic system is under pressure);
Elimination method: cleaning or replacement
5, pressure drop in the high pressure system
Causes: (1) High pressure system leakage;
Elimination method: check high pressure pipe joints and observation holes to eliminate leakage;
Cause: (2) Hydraulic system pressure drop or pressure mismatch
Elimination method: eliminate the cause of pressure drop in the hydraulic system or increase the hydraulic pressure;
Cause: (3) The hydraulic pump flow does not match
Elimination method: eliminate the cause of pressure drop in the hydraulic system or increase the hydraulic pressure;
Causes: (4) The hydraulic pump flow does not match
Elimination method: increase the flow of the hydraulic pump to match the high pressure system;
Cause: (5) One-way valve leaks (the phenomenon is hot);
Elimination method: repair or replace the hot check valve;
6, the pressure can not escape the ultra-high pressure system
Causes: (1) Plugged in energy converter;
Elimination methods: dismantling or replacement;
Cause: (2) The high pressure water switch is not turned on;
Elimination method: open high pressure water switch;